WIRING ON ML-116CNTL FOR THE 9 PIN SERIAL CONNECTOR     
IS AS FOLLOWS:                                          
                                                        
9 PIN MALE D    9 PIN FEMALE D                          
  TX  2------------2  RX                                
  RX  3------------3  TX                                
  GND 5------------5 GND                                
                                                        
COMMUNICATIONS PROTOCOL IS FIXED AT 38400, N, 8, 1      
                                                        
THIS PROGRAM UTILIZES 100% "TRUE FEEDBACK" FROM THE     
SWITCHER. THAT MEANS THAT WHEN A BUTTON IS PRESSED A    
COMMAND IS SENT TO THE SWITCHER WHICH THEN REACTS TO    
THAT BUTTON PRESS AND SENDS BACK AN UPDATED STATUS      
CODE. THAT CODE IS READ AND TRANSLATED INTO WHICH       
BUTTONS SHOULD BE LIT AND WHAT THE LEVELS OF THE BAR-   
GRAPHS ARE. BECAUSE OF THIS, NOTHING WILL HAPPEN        
UNLESS THE ML-116 IS PRESENT AND PROPER COMMUNICATION   
HAS BEEN ESTABLISHED.                                   
                                                        
THE PROGRAM EMULATES THE CONTROL AVAILABLE ON THE       
MONITOR PANEL AND MAP PANEL.  THE MONITOR PANEL ALLOWS  
CONTROL OF EACH ROOM BY SELECTING WHICH ROOM YOU WISH   
TO CONTROL AND "ROUTING" THE COMMANDS FROM ONE COMMON   
SET OF BUTTONS TO THAT ROOM.  THE MAP PANEL ALLOWS      
ROOM COMBINING AND HEAD TABLE SELECTION VIA A GRAPHIC   
REPRESENTATION OF THE ROOMS. IT WILL BE THE PROGRAMMERS 
RESPONSIBILITY TO CREATE A ROOM LAYOUT ON THE TOUCH     
PANEL AND PLACE THE MIX AND HEAD TABLE BUTTONS ON THE   
THE PAGE IN THE CORRECT LOCATION. REFER TO THE          
DOCUMENTATION SUPPLIED WITH THE SYSTEM TO DETERMINE     
ROOM NUMBERS AND MIX SWITCH NUMBERS, OR CONTACT FSR.    
                                                        
THIS CODE HAS BEEN PRESENTED TO YOU AS COURTESEY TO     
ASSIST YOU IN CONTROLLING THE FSR ML-116.  FSR MAKES    
NO WARRANTIES OR GUARANTEES AS TO THE ACCURACY OR       
USABLITIY OF THIS CODE NOR IS RESPONSIBLE FOR ANY LOSS  
OF TIME OR MONEY DUE TO ANY ERROR IN THIS CODE. ALL     
DATA HEREIN IS SUBJECT TO CHANGE WITHOUT NOTICE.        